3717-1-03.2(Y) / Miscellaneous sources of contamination.
CorrectedDuringInsp Food not protected from contamination. OBSERVED: Raw eggs above a beef roast in small reach in unit in dishroom. To prevent a cross contamination , Raw animal foods shall be stacked according to their minimum cooking temperature. CORRECTED: Employees switched items.
3717-1-04.8(E)(2) / Clean equipment and utensils stored in a self-draining position and covered or inverted.
CorrectedDuringInsp Clean equipment and utensils not stored in a self-draining position and covered or inverted. OBSERVED: Ice machine in the middle room with a bucket & pitcher not inverted. To prevent contamination from insects or dirt .Items for food use shall be inverted> CORRECTED: Employee inverted as needed.
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
Repeat Non-food contact surfaces of equipment are unclean. Clean as needed to not contaminate gloves/hands and prevent a food borne illness.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard/Critical Control Point
Inspection Date: 21-December-2022
Comments |
---|
Reviewed with Andy |
IV - P - Demonstration of Knowledge: The person in charge is Certified in Food Protection. II - P - Good Hygienic Practices: Food employee working with exposed foods, clean equipment, utensils, linens or unwrapped single-service or single use articles was not experiencing discharge from eyes, nose, or mouth. II - P - Good Hygienic Practices: Food employee was demonstrating good hygiene practices. IV - P - Demonstration of Knowledge:The operation is in compliance with Chapter 3717-1 of the Administrative Code. VII - P - Protection from Contamination: Observed raw animal foods separated by type during storage, preparation, holding, and display. III - P - Preventing Contamination by Hands: Observed food employee washing hands when required. III - P - Preventing Contamination by Hands: Observed food employee changing gloves when required. VI - P - TCS Food: Observed ready to eat TCS foods being properly date marked, and discarded when required. VI - P - TCS Food: Observed hot foods being held at 135°F or above; cold foods being held at 41°F or below. Food Process Reviewed: Reheating VII - P - Protection from Contamination: Observed employee properly cleaning and sanitizing food contact surfaces. III - P - Preventing Contamination by Hands: Observed food employee washing hands prior to donning single use gloves. II - P - Good Hygienic Practices: Food employee(s) were eating, drinking or using tobacco in designated area. X - P - Chemical: Sulfites are not applied to fresh fruits or vegetables intended for raw consumption. VIII - P - Consumer Advisory: Observed a consumer advisory on the menu for animal foods that are served raw, undercooked or not otherwise processed to eliminate pathogens. III - P - Preventing Contamination by Hands: Food employees were not contacting exposed ready-to-eat foods with bare hands. X - P - Chemical: No unapproved food or color additives are used. III - P - Preventing Contamination by Hands: Hand washing facilities are properly supplied. X - P - Chemical: Toxic materials are properly identified and stored. |