3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv. The ORP reading was 612.
Have the ACC unit inspected to determined why the ORP is low. Correct By: 21-Jul-2021
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat Required flow meter gauge was not maintained or not functional while the pool is in operation. The flow meter was stuck.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation. Correct By: 21-Jul-2021
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8. The pH was 7.0
Treat the pool water so that the pH is within the acceptable range. Correct By: 21-Jul-2021
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Repeat Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities. Correct By: 05-Jul-2021
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 21-June-2021
Comments |
---|
Ensure noted violations are corrected before next routine inspection. Otherwise, all other water parameters were within in requirements. |