[?] A summary of the violations found during the inspection are listed below.

3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low.
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test total alkalinity at least once/week.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry


3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided. No gauze or gloves
Provide first aid equipment, including a first aid kit, at the pool at all times.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 12-June-2023


Comments
Meter appears to be broken, ORP should be above 650, employee responsible for pool informed me this had been an ongoing issue. The first aid kit requires gauze and nitrile gloves. The main door to the pool should be fixed to close on its own. At this point in time the main door to the pool will remain ajar. Employees responsible for testing the water need to ensure they are measuring alkalinity every week. pH originally beyond 8.0. Corrected on site.