3701-31-04(D)(6)(a)(4) / Spa free chlorine disinfectant residual shall be above 2 ppm.
Critical Repeat Corrected During Inspection Spa free chlorine disinfectant residual was below 2 ppm. Corrected by 3.13.19
Do not operate the spa until the chlorine disinfectant residual is at 2 ppm or above.
3701-31-04 (B)(4)(a)(i) / Disinfection residuals are tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Repeat Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features. No readings were taken/recorded for today prior to pool opening. Corrected by 3.13.19
Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the disinfectant residual must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. Records were updated.
Facility Type: Spa
[?] Inspection Type: Follow-up
Inspection Date: 13-March-2019
Comments |
---|
Spoke with PIC during inspection- Other person on staff has been trained to take pool readings. Violations were corrected. thank you |