[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications.
All equipment must be maintained in accordance with the manufacturers specifications.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.


Inspection Information


Facility Type: Spa

[?] Inspection Type: Standard

Inspection Date: 21-June-2023


Comments
Remember, the chlorine of the Spa needs be above 2ppm and the water should be drained and replaced every 30 days. The flow meter was stuck and will need to be corrected in order to accurately calculate the turnover rate. The spa should filter its entire volume every 30 minutes. The alkalinity was low and need be maintained above 60ppm. The alkalinity should also be recorded weekly. The Ph need be maintained between 7.2-7.8.