3701-31-04 (B)(4)(a)(i) / Disinfection residuals are tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features. Pool chemicals are not being recorded until 1-2 hours after the pool has been open to the customers. Pool chemicals should be checked PRIOR to bathers entering the pool.
Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the disinfectant residual must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 24-January-2020
Comments |
---|
Pool chemicals are not being recorded until 1-2 hours after the pool has been open to the customers. Pool chemicals should be checked PRIOR to bathers entering the pool. |