[?] A summary of the violations found during the inspection are listed below.

3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
Repeat ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
3701-31-04 (D)(02) / Public swimming pool is continuously disinfected using a chemical feeding device connected to the circulation system
Critical Repeat The pool was not being continuously disinfected using a chemical feeding device connected to the circulation system.
Repair or replace the disinfection system so that the pool is continuously being disinfected. ACC is non-functioning. Chemistry is taken every 4 hours, files are on record.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 26-March-2024

Comments
The facility is clean at the time of inspection. ACC is alarming.