3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met. The turnover rate was only 144 gpm. The rate should be a minimum of 219 gpm.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve. Correct By: 09-Aug-2021
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm. The alkalinity was 40 ppm.
Raise the total alkalinity to at least 60 ppm. Correct By: 09-Aug-2021
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 30-July-2021
Comments |
---|
Ensure the noted findings are correct before next routine inspection. Otherwise, the spa was in good operating order at time of inspection. |