3701-31-04 (B)(1)(c) / Minimum disinfection residual provided as required
Critical Corrected During Inspection Chlorine disinfectant residual was less than 2 ppm for the spa. Equipment adjusted and spa at 3 ppm free chlorine.
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 2 ppm or above prior to placing the spa back into operation.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Corrected During Inspection pH was outside the range of 7.2 to 7.8. Equipment adjusted and pH is now at 7.4.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 26-March-2015