3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv. Observed at 435mv.
Have the ACC unit inspected to determined why the ORP is low. Correct By: 01-Jul-2022
3701-31-04(D)(6)(a)(2) / Pool free chlorine disinfectant residual shall be above 1 ppm.
Critical Pool free chlorine disinfectant residual was below 1 ppm. Observed at 0ppm
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. Correct By: 27-Jun-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 24-June-2022
Comments |
---|
Observed no chlorine in water chemistry test. ORP on ACC was also low. All other chemistry parameters met minimum requirements. Left warning sign noting that the pool was operating in violation of chapter 3701-31 with no chlorine residual. Ensure all noted findings are corrected prior to re-inspection. |