3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
The spa emergency button was not operating properly, it would not stop the jets from working when tested. A work order was placed for repair. Equipment was not maintained per manufacturers specifications.
All equipment must be maintained in accordance with the manufacturers specifications. Correct By: 31-Dec-2021
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8. The pH was 7.0. The PIC was working on spa and making adjustments during inspection.
Treat the pool water so that the pH is within the acceptable range. Correct By: 30-Nov-2021
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm. The total alkalinity was 30 ppm. The PIC was working on spa making adjustments during inspection.
Raise the total alkalinity to at least 60 ppm. Correct By: 30-Nov-2021
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 30-November-2021
Comments |
---|
Ensure the noted findings are correct before next routine inspection. Otherwise, all the other water parameters met requirements and paperwork was being filled out correctly. Good job! |