3701-31-04 (B)(4)(a)(iii) / pH is tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
pH was not tested daily at pool side and/or at required intervals for pools/automatic chemical controllers/special features. Pool is open from 7am to 11 pm, therefore, 2 readings must be taken per day.
pH must be tested prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use pH must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the pH must be tested at 1 special feature every 6 hours the sprayground or spray feature is in use.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
3701-31-04 (C)(8) / Spa water is drained at least every 30 days and is recorded
Spa water was not drained in the last 30 days. Please ensure spa drainage is documented on record sheets.
Drain spa immediately and clean before placing the spa back in operation.
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 12-November-2015
Comments |
---|
Please ensure the above are corrected prior to next inspection. Thank you. |