3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation. Flow meter was observed to be stuck. Unable to get flow reading.
Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation. Correct By: 01-Jul-2022
3701-31-04 (D)(7)(b) / pH and ORP values shall be displayed.
Critical ORP value was not displayed on the ACC unit. The ACC unit appeared to be unplugged. Unable to get ORP and pH reading via the ACC.
Have the ACC unit serviced or replaced so that the ORP value is displayed Correct By: 01-Jul-2022
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Repeat Emergency device (telephone) was not working. No dial tone was present.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities. Correct By: 01-Jul-2022
3701-31-04(D)(6)(a)(2) / Pool free chlorine disinfectant residual shall be above 1 ppm.
Critical Pool free chlorine disinfectant residual was below 1 ppm. Observed at 0.6ppm.
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. Correct By: 01-Jul-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 27-June-2022
Comments |
---|
Chlorine observed too low. ORP was not displayed. ACC appeared to be unplugged. Notified operator at time of inspection. Other water quality parameters within required limits. Flow meter observed to be stuck. Please ensure all noted findings are corrected prior to next inspection. |