[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters gauges was not functional while the pool is in operation. Required flow meter was not functional while the pool is in operation. The flow meter was stuck at 0.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation. Correct By: 30-Jun-2021
3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
A Type IV personal flotation device with 30 -60 foot throw line was provided at the unguarded pool. However, it was noted that the rope line was very worn and frayed. Please rope with new.
Provide a proper floatation device at all times. Correct By: 30-Jun-2021


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 15-June-2021

Comments
Ensure the noted findings are corrected before next routine inspection. Otherwise, all other water parameters met requirements. Gave operator pool license and asked they begin to keep proper records for pool for review.