[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (A) / All construction or alterations of a public swimming pool are approved
New disinfection system installed, automatic controller and acid feeder no longer being utilized.

3701-31-04 (B)(4)(a)(i) / Disinfection residuals are tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features. One reading being recorded each day for pool. Pool must be tested, and the results recorded, each morning prior to the pool being opened and every 4 hours thereafter as there is no longer an automatic controller being utilized.
Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the disinfectant residual must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 28-April-2017


Comments
Water chemistry within required parameters, no problems at time of inspection. Good.

Please submit Equipment Replacement Notification Form to Ohio Department of Health for approval of replacement equipment.