[?] A summary of the violations found during the inspection are listed below.

3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv. The auto controller alarm was activated and the reading was 0 mv. The PIC stated, a work order for repair has been placed.
Have the ACC unit inspected to determined why the ORP is low. Correct By: 29-Apr-2022
3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day. Correct By: 29-Apr-2022
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test total alkalinity at least once/week. Correct By: 29-Apr-2022


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 31-March-2022


Comments
Ensure noted findings are corrected before next routine inspection. Otherwise, all other water parameters were within requirements and reports were readily available at time of inspection. Good job!