3701-31-04 (B)(1)(c) / Minimum disinfection residual are provided as required
Critical Repeat No disinfection residual was present.
Add disinfectant until residual is minimum 1 ppm.
3701-31-04 (B)(1)(c) / Minimum disinfection residual are provided as required
Critical Repeat No disinfectant was present at the time of the inspection.
Add disinfectant to the pool until there is at least a minimum residual in the pool.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was 7.0
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was 8.0.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was 50 ppm.
Raise the total alkalinity to at least 60 ppm.
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 16-July-2014
Comments |
---|
Problems noted at the time of the inspection were addressed to staff on hand. |