3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range. Correct By: 24-Jan-2014
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm. Correct By: 24-Jan-2014
3701-31-04 (D)(6)(a) / Pool free chlorine disinfectant residual is above 1 ppm.
Pool free chlorine disinfectant residual was below 1 ppm.
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. Correct By: 24-Jan-2014
3701-31-04 (D)(7)(b) / pH and ORP values are displayed.
ORP value was not displayed on the ACC unit
Have the ACC unit serviced or replaced so that the ORP value is displayed Correct By: 24-Jan-2014
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 21-January-2014